BBTRZ Mineral Resistant Fire Cable

BBTRZ Mineral Insulated Cable

Model:
BBTRZ, NG-A(BTLY), BTLY, YTTWY, YTTW

Rated Voltage:
0.6/1 kV (standard), 450/750 V (for some types)

Specification:
Single core: 1.5 mm² – 630 mm²
Multi-core: 1.5 mm² – 400 mm² (cores: 2, 3, 4, 5, 3+1, 3+2, 4+1)

Features:
BBTRZ flexible mineral insulated fire-resistant cable features an inorganic mineral insulated wrapped construction. It is halogen-free and low-smoke, achieving bunched ZA class flame retardance. Fire resistance complies with BS6387 Category C, maintaining circuit integrity for 180 minutes under 950°C flame conditions. Maximum continuous conductor operating temperature is 90°C, and short-circuit temperature can reach 250°C (duration ≤5 s). The cable offers good flexibility, can be supplied in fixed lengths, and is easy to install with a long service life.

Application:
Suitable for high-rise buildings, subways, airports, power plants, fire-fighting systems, and other critical circuits requiring circuit integrity under fire conditions. Can be installed on trays, in conduits, or directly buried.

Product Details

Type Voltage Construction
BBTRZ 0.6/1 kV Copper conductor mineral insulated wrapped construction LSZH flexible fire-resistant cable (GB/T 34926)
NG-A(BTLY) 0.6/1 kV Copper conductor mineral insulated aluminium sheath isolated LSZH fire-resistant cable, Class A flame retardant (GB/T 34926)
BTLY 0.6/1 kV Copper conductor mineral insulated aluminium sheath isolated LSZH fire-resistant cable (GB/T 34926)
YTTWY 0.6/1 kV Copper conductor mineral insulated corrugated copper sheath LSZH flexible fire-resistant cable (GB/T 34926)
YTTW 0.6/1 kV Copper conductor mineral insulated corrugated copper sheath flexible fire-resistant cable (GB/T 34926)
Note: All above cables comply with GB/T 34926. Fire resistance meets GB/T 19216 and IEC 60331, with reference to BS 6387 and other international fire resistance standards. The IEC standard does not assign specific type designations; Chinese national or industry type names are commonly used.


Type Voltage Number of Cores Nominal CSA (mm²)
BBTRZ 0.6/1 kV 1 1.5~630
BBTRZ 0.6/1 kV 2 1.5~185
BBTRZ 0.6/1 kV 3 1.5~400
BBTRZ 0.6/1 kV 4, 5 1.5~300
BBTRZ 0.6/1 kV 3+1, 3+2, 4+1 4~400
NG-A(BTLY) 0.6/1 kV same as above same as above
BTLY 0.6/1 kV same as above same as above
YTTWY 0.6/1 kV same as above same as above
YTTW 0.6/1 kV same as above same as above
Note: Higher voltage ratings and special constructions available upon request.