BVVB Flat PVC Cable
BVVB Copper Core PVC Insulated and Sheathed Flat Cable
Model:
RVV, BVV, BVVB, BLVVB, RVVP
Rated Voltage:
300/500 V
Specification:
0.75 mm² – 10 mm² (2~3 cores)
Features:
Temperature rating: 70°C; service life ≥ 30 years. Resistant to acid, alkali, oil, moisture and mildew; excellent electrical insulation and abrasion resistance. The flat sheath construction saves installation space and is suitable for neat surface mounting along walls, ceilings, or in trunking, with additional mechanical protection from the sheath.
Application:
For fixed wiring in building lighting, socket circuits, etc. with AC rated voltage U₀/U up to 300/500 V. Particularly suitable for indoor distribution where surface mounting or neat arrangement in trunking is required.
Model:
RVV, BVV, BVVB, BLVVB, RVVP
Rated Voltage:
300/500 V
Specification:
0.75 mm² – 10 mm² (2~3 cores)
Features:
Temperature rating: 70°C; service life ≥ 30 years. Resistant to acid, alkali, oil, moisture and mildew; excellent electrical insulation and abrasion resistance. The flat sheath construction saves installation space and is suitable for neat surface mounting along walls, ceilings, or in trunking, with additional mechanical protection from the sheath.
Application:
For fixed wiring in building lighting, socket circuits, etc. with AC rated voltage U₀/U up to 300/500 V. Particularly suitable for indoor distribution where surface mounting or neat arrangement in trunking is required.
Category:
Product Details

| CABLE TYPE & CONSTRUCTION | ||
| Type | Voltage | Construction |
| 60227 IEC 05(BV) | 300/500V | Single core PVC insulated non-sheathed cable with solid copper conductor(class 1) for internal wiring 70℃ |
| 60227 IEC 07(BV-90) | 300/500V | Single core PVC insulated non-sheathed cable with solid copper conductor(class 1) for internal wiring 90℃ |
| 60227 IEC 01(BV) | 450/750V | Single core PVC insulated non-sheathed cable with rigid copper conductor(class 1, class 2) for general purpose 70℃ |
| 60227 IEC 06(RV) | 300/500V | Single core PVC insulated non-sheathed cable with flexible copper conductor(class 5) for internal wiring 70℃ |
| 60227 IEC 08(RV-90) | 300/500V | Single core PVC insulated non-sheathed cable with flexible copper conductor(class 5) for internal wiring 90℃ |
| 60227 IEC 02(RV) | 450/750V | Single core PVC insulated non-sheathed cable with flexible copper conductor(class 5) for general purpose 70℃ |
| BVR | 450/750V | Single core PVC insulated non-sheathed cable with flexible copper conductor (JB/T 8734) |
| BLV | 450/750V | Single core PVC insulated non-sheathed cable with aluminium conductor (JB/T 8734) |
| 60227 IEC 52(RVV) | 300/300V | Light PVC insulated and sheathed cords with flexible copper conductor(class 5) for fixed wiring 70℃ |
| 60227 IEC 53(RVV) | 300/500V | Ordinary PVC insulated and sheathed cords with flexible copper conductor(class 5) for fixed wiring 70℃ |
| 60227 IEC 10(BVV) | 300/500V | Light PVC insulated and sheathed cables with rigid copper conductor(class 1, class 2) for fixed wiring 70℃ |
| BVVB | 300/500V | PVC insulated and sheathed flat cable with rigid copper conductor (JB/T 8734) |
| BLVVB | 300/500V | PVC insulated and sheathed flat cable with aluminium conductor (JB/T 8734) |
| RVS | 300/300V | PVC insulated twisted pair flexible cable with flexible copper conductor mostly used fire alarm system (JB/T 8734) |
| RVVP | 300/300V | PVC insulated and sheathed flexible cable with flexible copper conductor and bare or tinned copper wire braid screen (JB/T 8734) |
| Available Options (Add Prefix to Model): Flame Retardant Type: Add ZC-, ZB-, ZA- before the model. Fire Resistant Type: Add N- before the model. Flame Retardant & Fire Resistant Type: Add ZCN-, ZBN-, ZAN- before the model. | ||
| NUMBER OF CORES & CROSS-SECTIONAL AREA | |||
| Type | Voltage | Number of core | Nominal CSA (mm2) |
| 60227 IEC 05(BV) | 300/500V | 1 | 0.5~1.0 |
| 60227 IEC 07(BV-90) | 300/500V | 1 | 0.5~2.5 |
| 60227 IEC 01(BV) | 450/750V | 1 | 1.5~400 |
| 60227 IEC 06(RV) | 300/500V | 1 | 0.5~1.0 |
| 60227 IEC 08(RV-90) | 300/500V | 1 | 0.5~2.5 |
| 60227 IEC 02(RV) | 450/750V | 1 | 1.5~240 |
| BVR | 450/750V | 1 | 0.75~185 |
| BLV | 450/750V | 1 | 2.5~400 |
| 60227 IEC 52(RVV) | 300/300V | 2~3 | 0.5~0.75 |
| 60227 IEC 53(RVV) | 300/500V | 2~5 | 0.75~2.5 |
| 60227 IEC 10(BVV) | 300/500V | 2~5 | 1.5~35 |
| BVVB | 300/500V | 2~3 | 0.75~10 |
| BLVVB | 300/500V | 2~3 | 0.75~10 |
| RVS | 300/300V | 2 | 0.5~6 |
| RVVP | 300/300V | 2~7 | 0.5~2.5 |